Fully labelled domestic consumer unit after EICR testing

CJA Electrical does EICR testing across Meopham and the wider Gravesham area — landlords ahead of a new tenancy or a 5-yearly recheck, homeowners buying or selling or just due an inspection, and anyone who’s noticed warm sockets, frequent tripping, or a burning smell they can’t explain. Meopham sits within the 30-minute working radius of our Rochester base, so site visits are tight to the diary and reports come back inside 48 hours.

What EICR actually is

An EICR is a formal inspection and test of the fixed wiring in a property — the consumer unit, every circuit running off it, every accessible socket, switch, and light fitting. The output is a written report with observation codes against anything that’s not satisfactory: C1 for immediate danger, C2 for potentially dangerous (also a fail), C3 for improvement recommended, FI for further investigation required. A satisfactory report has no C1 or C2 observations. A property with C3 observations alone still passes. The report is what landlords need for the PRS regulations, what surveyors check on sale, and what insurers reference when validating a claim.

When you need EICR in Meopham

Different reasons for different property types. Rented property in Meopham runs on the 2020 PRS regulations — five years between inspections, plus a fresh report at the start of each new tenancy. The certificate is supplied to tenants and to the local authority on request. Owner-occupied property doesn’t have a statutory cycle. IET guidance is 10 years for domestic, but plenty of homeowners inspect more frequently — usually around major life events like buying, selling, or renovating. Insurance renewals also trigger it, especially on older properties or where there’s been a previous claim.

Multi-occupancy meter cupboard with separate consumer units and smart meters
Multi-occupancy meter cupboard with separate consumer units and smart meters

Standards and what compliance looks like

The two regulatory references that matter on a Meopham EICR are BS 7671 (the technical standard the inspection works to) and, for rental property, the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 (the law requiring landlords to have a current report). The current edition of BS 7671 is the 18th Edition with Amendment 2 (2022). Reports reference the edition in force at the date of inspection. The PRS regulations require the certificate to be supplied to tenants within 28 days of the inspection and to Gravesham Borough Council on request within 7 days.

Fittings and where they go

Inspection scope is “what’s accessible without destruction” — we don’t lift floorboards or break into walls. The consumer unit comes off, every socket and switch plate is checked visually, every light fitting that’s reachable is inspected, and we go into lofts, cellars, outbuildings, and meter cupboards where they exist. For the hidden parts of the installation — buried cables, junctions inside walls — the live testing catches structural faults via insulation resistance (low values mean cable damage or moisture ingress) and earth fault loop impedance (high values mean a poor earth path). The combination of visual and test results is what builds the picture of installation condition.

Smaller domestic consumer unit with each circuit clearly labelled
Smaller domestic consumer unit with each circuit clearly labelled

Testing schedule and remedials

Testing splits into dead testing (with the circuit isolated) and live testing (with the supply restored). Dead tests cover continuity of protective conductors, insulation resistance between live and earth, polarity, and ring final continuity on socket circuits. Live tests cover earth fault loop impedance, prospective fault current, and RCD operation times. Each circuit’s results are recorded individually on the schedule of test results that accompanies the certificate. For a typical three-bed property in Meopham the on-site time is half a day. Larger or older properties with more circuits can take a full day. The brief power-down for dead testing on each circuit is usually a few minutes per circuit — long enough to put kettles and computers off the boil, short enough that nothing in the fridge defrosts.

Why Meopham property owners book CJA Electrical

CJA Electrical is based in Rochester and covers EICR work across Gravesham from there. Meopham sits within the 30-minute working radius — close enough that scheduling is tight, return visits for remedial work are easy, and you’re dealing with someone who knows the local stock. We do mostly residential EICR plus increasingly commercial fixed-wire work as the client base has grown. Qualifications: City & Guilds 2391 (Inspection & Testing), 2382 (18th Edition Wiring Regulations), and 2365 (Diploma in Electrical Installation). Calibrated test equipment. Certificates supplied as PDF inside 48 hours. Remedial work quoted separately so the price is clear and you can plan the budget.

How the work runs

The flow is simple. First contact (phone, email, or WhatsApp) to confirm the property size, circuit count, and rough timing. A quote — fixed price for most Meopham domestic EICRs, given on the call. A scheduled inspection visit, typically inside the working week. The written report supplied as a PDF inside 48 hours of testing completing. If anything is unsatisfactory, remedial work is quoted separately. Once remedials are done, the affected circuits are re-tested and a fresh, satisfactory certificate is issued. Most landlord and pre-sale jobs run start-to-finish in a working week; commercial and larger residential might take a fortnight including remedials.

What affects the price

The two factors that move Meopham EICR pricing are circuit count (more circuits = more testing time) and complexity (multiple consumer units, outbuildings, three-phase supplies on commercial property). For straightforward domestic property, the price band is well-established and quoted up-front. What we don’t do: deposits, hidden fees, or surprise charges on the day. The fixed price is what you pay, invoiced on completion. Remedials are separate so the EICR price is the EICR price.

FAQs

What’s the difference between a Satisfactory and Unsatisfactory report?

A satisfactory report has no C1 (immediate danger) or C2 (potentially dangerous) observations. C3 observations (improvement recommended) on their own don’t fail the report. An unsatisfactory report means C1 or C2 observations are present and the installation needs remedial work to bring it back to compliance.

Can you do remedial work on the same visit?

Sometimes — minor remedials (replacing a damaged socket face, tightening a loose connection, fitting a missing blanking plate) can be done on the inspection visit if time and parts allow. Larger remedial work (consumer unit replacement, recircuiting, additional RCD protection) is quoted separately and scheduled as a follow-up.

Will the inspection damage anything?

No. The tests are non-destructive. Insulation resistance and earth fault loop are low-current measurements that don’t stress the installation. Most of the on-site work is visual inspection plus brief electrical testing on each circuit. The only disruption is the short power-downs during dead testing.

How quickly can I get a report after the inspection?

PDF inside 48 hours of testing completing. We can usually turn it around faster (same evening, next morning) if there’s a deadline — landlord renewal, sale exchange, insurance renewal — and we just need to know the deadline up front.

What if I disagree with an observation on the report?

Talk to us. Each observation has reasoning behind the coding — usually clear regulatory references — and we’ll walk through any specific item if you want to understand the call. Genuine reconsideration on borderline calls is fine; we don’t dig in for the sake of it.

Does an EICR cover gas, water, or appliances?

No. The EICR is a fixed-wiring inspection only — the consumer unit and circuits, plus accessories like sockets and switches. Gas certification is a Gas Safe registered engineer’s job; water leak detection is a plumber’s; appliance testing (PAT testing) is a separate service. We can refer to trusted local trades for any of those.

Related services in Meopham

EICR in nearby towns

Frequently asked questions

What's the difference between a Satisfactory and Unsatisfactory report?

A satisfactory report has no C1 (immediate danger) or C2 (potentially dangerous) observations. C3 observations (improvement recommended) on their own don't fail the report. An unsatisfactory report means C1 or C2 observations are present and the installation needs remedial work to bring it back to compliance.

Can you do remedial work on the same visit?

Sometimes — minor remedials (replacing a damaged socket face, tightening a loose connection, fitting a missing blanking plate) can be done on the inspection visit if time and parts allow. Larger remedial work (consumer unit replacement, recircuiting, additional RCD protection) is quoted separately and scheduled as a follow-up.

Will the inspection damage anything?

No. The tests are non-destructive. Insulation resistance and earth fault loop are low-current measurements that don't stress the installation. Most of the on-site work is visual inspection plus brief electrical testing on each circuit. The only disruption is the short power-downs during dead testing.

How quickly can I get a report after the inspection?

PDF inside 48 hours of testing completing. We can usually turn it around faster (same evening, next morning) if there's a deadline — landlord renewal, sale exchange, insurance renewal — and we just need to know the deadline up front.

What if I disagree with an observation on the report?

Talk to us. Each observation has reasoning behind the coding — usually clear regulatory references — and we'll walk through any specific item if you want to understand the call. Genuine reconsideration on borderline calls is fine; we don't dig in for the sake of it.

Does an EICR cover gas, water, or appliances?

No. The EICR is a fixed-wiring inspection only — the consumer unit and circuits, plus accessories like sockets and switches. Gas certification is a Gas Safe registered engineer's job; water leak detection is a plumber's; appliance testing (PAT testing) is a separate service. We can refer to trusted local trades for any of those.

Get a quote

Send a quick message and you'll get a same-day reply during working hours. Skip straight to phone or WhatsApp if you prefer.

EICR detail (helps with the quote)

Or skip the form: Call 07598 216512 WhatsApp info@cjaelectrical.co.uk