Aico 3000 Series smoke and heat alarms ready for installation

Mains-wired interlinked smoke and heat alarm installation in Aylesford — for landlords meeting smoke alarm regulations on rented homes and HMOs, homeowners upgrading from old battery-only alarms, and anyone fitting out a new kitchen who needs a heat alarm added. CJA Electrical is an Aico Expert Installer fitting Aico 3000 Series across Maidstone, with the install signed off to BS 5839-6.

What Alarms actually is

A modern domestic smoke alarm system has three component types: smoke alarms (in circulation spaces — landings, hallways), heat alarms (in kitchens where smoke alarms would false-trigger), and carbon monoxide alarms (where there’s a fixed combustion appliance — boiler, gas fire, wood burner). All three are wired to mains supply with battery backup, and all three interlink so that one going off triggers them all. The system runs on Grade D1 power supply (mains plus sealed rechargeable battery backup) for most Aylesford domestic property, with grades stepped up for HMOs and larger installations depending on the BS 5839-6 risk assessment.

When you need Alarms in Aylesford

The triggers for new alarm installation work in Aylesford: a rented property compliance check (the 2022 amendment regs require minimum coverage), an HMO licence application or renewal (council typically specifies a higher BS 5839-6 grade), a sale or purchase where the surveyor flags inadequate smoke detection, a kitchen renovation needing a heat alarm, or simply a homeowner deciding it’s time to retire the 1990s battery-only alarms. For new-build property the original installer will have fitted the system, but those alarms reach end-of-life around 8-10 years in (battery-backed Grade D1) and need replacement on a similar cycle. We swap end-of-life alarms on a like-for-like basis where the existing layout and grading is sound.

Multifunction tester measuring end-to-end resistance on a ring final circuit
Multifunction tester measuring end-to-end resistance on a ring final circuit

Standards and what compliance looks like

The technical standard for domestic smoke alarms in the UK is BS 5839-6 — “Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises”. The standard sets out grades (A, B, C, D1, D2, F) covering different supply configurations and protection levels, with Grade D1 (mains + sealed 10-year battery, interlinked) the standard for most Aylesford domestic property. For HMO common parts, the standard typically steps up to Grade A (panel-based) or Grade B depending on the building size and complexity. Tonbridge and Malling Borough Council will specify the required grade as part of the HMO licence conditions.

Fittings and where they go

Where each alarm goes on a Aylesford domestic install: Smoke alarms — circulation spaces. Landings, hallways, top and bottom of stairs. Mounted to the ceiling at least 300 mm from any wall or light fitting. Heat alarms — kitchens. Mounted to the ceiling, away from the cooker hood, where rising heat would reach the alarm promptly without interference from steam or oil vapour. CO alarms — mounted near (not directly over) any fixed combustion appliance: boiler, gas fire, wood burner. Manufacturer guidance specifies horizontal and vertical distances; we follow the Aico install guide on each fitting. Multi-sensor alarms (combined smoke + heat) are an option in some scenarios — useful in open-plan kitchen-diner layouts where a pure smoke alarm would false-trigger on cooking.

Fully labelled domestic consumer unit after EICR testing
Fully labelled domestic consumer unit after EICR testing

Testing schedule and remedials

BS 5839-6 specifies a monthly test cycle on Grade D1 systems — the householder presses the test button on each alarm to confirm it sounds and that the interlinking is operating. For HMOs and larger installations, weekly testing of common- parts alarms is typical, with quarterly full-discharge testing on Grade A panel systems. Annual servicing is good practice on any installed system — a competent person tests each alarm, checks battery condition, and verifies the interlink. CJA Electrical does the annual service on systems we’ve installed and on systems installed by others.

Why Aylesford property owners book CJA Electrical

Aico Expert Installer status matters because alarm installation isn’t just “screw the unit to the ceiling and plug it in”. Siting, interlinking method, kitchen versus hallway placement, CO alarm proximity to combustion appliances — there are real install decisions that affect whether the system actually performs in a fire. Manufacturer training is what makes those decisions consistent. CJA Electrical is based in Rochester and covers smoke alarm work across Maidstone. Aylesford sits within the 25-minute working radius. The 3000 Series is the kit we install by default, the BS 5839-6 certificate goes out same-day after install, and we stand behind the work.

How the work runs

Most Aylesford domestic alarm installs run as a single-visit job after a brief site survey. The survey takes 30 minutes and confirms positions, interlink method, and any specific layout constraints (low ceilings, sloped landings, kitchen geometry). Quote follows within a working day. Install day — half a day on site. We mount each alarm, interlink wirelessly via SmartLINK (or hard-wire if that’s what the property calls for), test the system, walk the householder through the monthly test procedure, and supply the BS 5839-6 certificate as a PDF. Annual servicing, if the householder wants it scheduled, is booked directly into the diary at install time.

What affects the price

Pricing splits into alarms and labour. Alarm hardware is Aico 3000 Series at trade pricing (typically £40-£60 per unit depending on type), with the labour reflecting install time, interlink commissioning, and certification. For most Aylesford domestic property the all-in fixed price is set after a site survey. Bulk pricing for HMOs and portfolio landlords reflects the economies of scale on multi-alarm installs. Annual servicing on installed systems is a separate quoted item, typically booked at the same time as the original install if requested.

FAQs

Do I need a CO alarm too?

If the property has any fixed combustion appliance — gas boiler, gas fire, wood burner, oil boiler — yes. The Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 require a CO alarm in any room used as living accommodation where there’s a fixed combustion appliance. We fit Aico Ei3018 CO alarms as part of the same install, interlinked with the smoke alarms.

What documentation do I get after the install?

A BS 5839-6 certificate documenting the install — alarm types, locations, interlink method, supply, and the commissioning test result. Plus a logbook for ongoing monthly test records that stays at the property. The certificate is what fire risk assessors, councils, insurers, and (for landlord property) tenants will expect to see.

Will the alarms false-trigger on burnt toast?

Less than older alarms used to. Modern Aico optical smoke alarms have improved discrimination between cooking smoke and real fire smoke, but they’re still siting-sensitive — a smoke alarm too close to a kitchen door will occasionally false-trigger on heavy cooking. The fix is a heat alarm in the kitchen and a smoke alarm in the hallway with adequate distance. We site to BS 5839-6 spec to minimise nuisance triggers.

What standard do smoke alarms need to meet?

BS 5839-6 is the standard for domestic smoke and heat alarms. For most Aylesford homes, Grade D1 mains-wired alarms with sealed battery backup are appropriate. HMOs and larger properties may need a higher grade — we’ll advise on what your specific property requires.

Do smoke alarms need to be interlinked?

For new installations, yes — interlinked alarms (where one going off triggers all of them) are the current standard. Interlinking can be done by hard wire or by radio frequency depending on what’s easier in the property. Aico’s SmartLINK RF protocol is the default on the 3000 Series.

Related services in Aylesford

Alarms in nearby towns

Frequently asked questions

Do I need a CO alarm too?

If the property has any fixed combustion appliance — gas boiler, gas fire, wood burner, oil boiler — yes. The Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 require a CO alarm in any room used as living accommodation where there's a fixed combustion appliance. We fit Aico Ei3018 CO alarms as part of the same install, interlinked with the smoke alarms.

What documentation do I get after the install?

A BS 5839-6 certificate documenting the install — alarm types, locations, interlink method, supply, and the commissioning test result. Plus a logbook for ongoing monthly test records that stays at the property. The certificate is what fire risk assessors, councils, insurers, and (for landlord property) tenants will expect to see.

Will the alarms false-trigger on burnt toast?

Less than older alarms used to. Modern Aico optical smoke alarms have improved discrimination between cooking smoke and real fire smoke, but they're still siting-sensitive — a smoke alarm too close to a kitchen door will occasionally false-trigger on heavy cooking. The fix is a heat alarm in the kitchen and a smoke alarm in the hallway with adequate distance. We site to BS 5839-6 spec to minimise nuisance triggers.

What standard do smoke alarms need to meet?

BS 5839-6 is the standard for domestic smoke and heat alarms. For most Aylesford homes, Grade D1 mains-wired alarms with sealed battery backup are appropriate. HMOs and larger properties may need a higher grade — we'll advise on what your specific property requires.

Do smoke alarms need to be interlinked?

For new installations, yes — interlinked alarms (where one going off triggers all of them) are the current standard. Interlinking can be done by hard wire or by radio frequency depending on what's easier in the property. Aico's SmartLINK RF protocol is the default on the 3000 Series.