Labelled consumer unit in a rented property after a landlord EICR

Landlord EICR testing for Faversham private rented property. Same-week appointments across the area, written report inside 48 hours of testing, certificates supplied in the BS 7671 Appendix 6 format that Swale Borough Council and every major letting agent recognises. Tenant access can be arranged via the agent or directly with the tenant — whichever is easier — and the inspection itself is non-disruptive enough to fit into a single morning or afternoon visit.

What Landlord EICR actually is

A landlord EICR is the same fundamental inspection as any EICR — a visual check of the consumer unit and accessible accessories, plus dead and live testing on every circuit — but commissioned to satisfy the 2020 PRS regulations. The output is a written report against BS 7671:2018+A2:2022, with observation codes (C1/C2/C3/FI) on anything that doesn’t meet the regulations. What’s specific to the landlord version is the documentation flow: the certificate must be supplied to existing tenants within 28 days of the inspection, to new tenants before they take occupation, and to Swale Borough Council on request within 7 days. Reports formatted to the standard BS 7671 layout are accepted across the industry.

When you need Landlord EICR in Faversham

The 5-yearly cycle plus new-tenancy rule is the headline. The practical scheduling reality for most Faversham landlords is a rolling diary — set a reminder a couple of months before the certificate expires and book the re-test in good time so any remedials don’t bump the property into out-of-compliance territory at the renewal date. Letting agents typically manage this on behalf of the landlord via a portfolio diary; private landlords often track it via the expiry date on their last certificate. Either way, getting the inspection done a couple of months ahead of expiry gives breathing room for any remedials needed before the deadline actually bites.

Inside a fully wired domestic consumer unit
Inside a fully wired domestic consumer unit

Standards and what compliance looks like

The two pieces of paperwork that matter on a landlord EICR are the certificate itself (signed against BS 7671:2018+A2:2022) and the schedule of test results (the appendix recording each individual circuit’s test measurements). Both go to the tenant within 28 days of the inspection and to the council within 7 days of any request. Standards-wise, landlord EICRs aren’t held to a different technical bar than owner-occupied EICRs — same Wiring Regulations, same observation codes, same testing tolerances. The difference is the regulatory wrapper: defined cycle, defined paper trail, defined penalties.

Testing schedule and remedials

On site, landlord EICR testing is non-disruptive — the work is quiet, brief power-downs are limited to 5-10 minutes per circuit, and the testing equipment is non-destructive. Tenants typically don’t need to be home for the whole visit, just to provide access at the start. Testing follows the standard BS 7671 sequence: inspection of the consumer unit and accessories first, then dead testing (continuity, insulation resistance, polarity, ring continuity) on each circuit, then live testing (earth fault loop, RCD operation) once the supply’s restored. Each circuit’s results are recorded individually on the schedule of test results.

RCD and loop impedance testing in progress on a domestic circuit
RCD and loop impedance testing in progress on a domestic circuit

Why Faversham property owners book CJA Electrical

CJA Electrical works with private landlords and letting agents across Swale. Faversham sits within the 35 -minute working radius of our Rochester base, so scheduling around tenant availability is straightforward and re-tests after remedial work happen quickly. What landlords and agents tell us matters: same-week appointments, certificates inside 48 hours, reports formatted to satisfy Swale Borough Council requests, and remedial work quoted clearly so the budget decision is straightforward. Same person on site, same person signing the certificate, no subcontracting.

How the work runs

Step one — the booking. We need property details (address, bedrooms, rough age of installation, any known issues) and the contact for tenant access (agent or tenant direct). Quote confirmed on that call for standard property; site visit first for unusual installations or HMO conversions. Step two — the testing visit. Half a day for most Faversham three-bed rental property; longer for HMOs and larger conversions. Brief power-downs during dead testing flagged in advance to the tenant. Property left exactly as found. Step three — the report. PDF inside 48 hours, supplied to landlord and agent. Remedials, if needed, quoted separately. Re-test scheduled once remedials are complete.

What affects the price

The two factors that move Faversham landlord EICR pricing are circuit count (more circuits = more testing time) and access (single visit with full tenant cooperation versus multiple return visits). For straightforward domestic rental property with cooperative tenant access, the price is well-established and quoted up-front. What we don’t do: deposits, hidden charges, or fees beyond the quoted price. The fixed price is what’s invoiced on completion. Remedials are separate so the EICR price is the EICR price.

FAQs

How fast can I get a certificate if I need one urgently?

Same-week is standard. If a tenant move-in or insurance renewal deadline is tight, we can usually fit an inspection in within 24-48 hours of booking. Reports are turned around same-evening or next-morning where the deadline calls for it — just let us know up front.

Do I need a separate certificate for each property in my portfolio?

Yes. Each rental property needs its own EICR — addresses, circuit details, and observations are property-specific. For portfolio landlords with several properties due at the same time, we can schedule the visits efficiently and bulk-deliver the certificates so the agent has the full portfolio in hand at once.

What about EICRs for HMOs?

HMO landlord EICRs follow the same 5-yearly cycle as ordinary rented homes, but typically also align with the HMO licence cycle issued by Swale Borough Council. HMOs often have shared common-parts circuits (corridor lighting, fire alarm interface, escape route lighting) that get tested separately. We work to whatever the council specifically requires for the licence renewal.

Do I have to do an EICR every 5 years on a rental?

Yes. Since June 2020, every privately rented home in England must have a satisfactory EICR every 5 years and at the start of each new tenancy. The certificate must be supplied to tenants within 28 days of the inspection and to Swale Borough Council on request within 7 days.

What happens if I don’t have a current EICR?

Swale Borough Council can serve a remedial notice requiring you to bring the installation into compliance within a fixed timescale, and can issue civil penalties of up to £30,000 for non-compliance. Insurers may also refuse to honour claims related to electrical incidents on properties without current certification.

How is tenant access arranged?

Either through your letting agent or directly with the tenant — whichever is easier for you. We coordinate the visit a few days in advance, confirm the appointment with the tenant, and work around their schedule for the testing visit itself. Most testing visits take a single morning or afternoon.

Can the certificate be sent direct to my agent?

Yes. The PDF can go to you, your letting agent, your council, or all of the above. Swale Borough Council accepts the standard BS 7671 Appendix 6 format, as do all the major letting agents and managing agents we’ve worked with.

Related services in Faversham

Landlord EICR in nearby towns

Frequently asked questions

How fast can I get a certificate if I need one urgently?

Same-week is standard. If a tenant move-in or insurance renewal deadline is tight, we can usually fit an inspection in within 24-48 hours of booking. Reports are turned around same-evening or next-morning where the deadline calls for it — just let us know up front.

Do I need a separate certificate for each property in my portfolio?

Yes. Each rental property needs its own EICR — addresses, circuit details, and observations are property-specific. For portfolio landlords with several properties due at the same time, we can schedule the visits efficiently and bulk-deliver the certificates so the agent has the full portfolio in hand at once.

What about EICRs for HMOs?

HMO landlord EICRs follow the same 5-yearly cycle as ordinary rented homes, but typically also align with the HMO licence cycle issued by Swale Borough Council. HMOs often have shared common-parts circuits (corridor lighting, fire alarm interface, escape route lighting) that get tested separately. We work to whatever the council specifically requires for the licence renewal.

Do I have to do an EICR every 5 years on a rental?

Yes. Since June 2020, every privately rented home in England must have a satisfactory EICR every 5 years and at the start of each new tenancy. The certificate must be supplied to tenants within 28 days of the inspection and to Swale Borough Council on request within 7 days.

What happens if I don't have a current EICR?

Swale Borough Council can serve a remedial notice requiring you to bring the installation into compliance within a fixed timescale, and can issue civil penalties of up to £30,000 for non-compliance. Insurers may also refuse to honour claims related to electrical incidents on properties without current certification.

How is tenant access arranged?

Either through your letting agent or directly with the tenant — whichever is easier for you. We coordinate the visit a few days in advance, confirm the appointment with the tenant, and work around their schedule for the testing visit itself. Most testing visits take a single morning or afternoon.

Can the certificate be sent direct to my agent?

Yes. The PDF can go to you, your letting agent, your council, or all of the above. Swale Borough Council accepts the standard BS 7671 Appendix 6 format, as do all the major letting agents and managing agents we've worked with.

Get a quote

Send a quick message and you'll get a same-day reply during working hours. Skip straight to phone or WhatsApp if you prefer.

EICR detail (helps with the quote)

Or skip the form: Call 07598 216512 WhatsApp info@cjaelectrical.co.uk