LED emergency exit sign with running-man pictogram fitted by CJA Electrical

CJA Electrical fits, tests, and remediates emergency lighting across Rainham and the wider Medway area. The standard for non-domestic premises and HMO common parts is BS 5266 — that’s the framework Medway Council, fire risk assessors, and insurers expect to see referenced on a current certificate. Whether you’re installing a new system, retesting an existing one, or fixing fittings flagged on a fire risk assessment, the work runs out of our Rochester base.

What Emergency Lighting actually is

Emergency lighting is a battery-backed lighting system that switches on automatically when the mains supply fails. Its only job is keeping escape routes lit long enough for occupants to get out safely — not general illumination. For any premises where it’s required by law, a BS 5266 system is the documentation regulators expect to see. For most Rainham property where it applies — HMOs, blocks of flats, mixed-use buildings with shared corridors — the spec involves non-maintained LED bulkhead fittings at strategic points (stair heads, corridor junctions, exit doors), with a 3-hour battery duration matched to sleeping accommodation requirements.

When you need Emergency Lighting in Rainham

The headline rule for Rainham is the Regulatory Reform (Fire Safety) Order 2005, which requires every non-domestic premises to have a fire risk assessment that addresses escape route lighting. In practice, the properties that need emergency lighting in Medway are HMOs, blocks of flats with shared common parts, converted-house flats with shared escape routes, and any commercial or mixed-use premises. Medway Council will normally write emergency lighting into the HMO licence directly. For commercial premises, the duty-holder (employer or building owner) is on the hook under the FSO; the fire risk assessor’s findings drive the spec.

Multifunction tester measuring end-to-end resistance on a ring final circuit
Multifunction tester measuring end-to-end resistance on a ring final circuit

Standards and what compliance looks like

Compliance under BS 5266 means the fittings are in the right places, the right grade, and the right duration. The standard distinguishes between fittings that need to come on automatically when the mains fails (non-maintained, the common case) and fittings that stay on the whole time (maintained, used where continuous light is needed). Duration ratings matter. Sleeping accommodation — and that includes any HMO licensed by Medway Council — requires 3-hour fittings. 1-hour fittings are acceptable in commercial premises with quick evacuation only. We default to 3-hour LED for residential applications because the cost difference is minimal and the compliance posture is stronger.

Fittings and where they go

The kit we typically install on Rainham HMO common parts: - 3-hour LED bulkheads mounted at corridor and landing locations identified by the FRA - 3-hour LED exit signs with the appropriate arrow direction at final exits - Sealed lithium-cell batteries integrated into each fitting (10-year design life) - Test switches sited where the duty owner can reach them for monthly checks - Permanent live feeds taken from a regularly-used lighting circuit so the battery stays charged when the building is occupied All fittings are EN 60598-2-22 compliant and self-test-capable on higher-spec models.

Smaller domestic consumer unit with each circuit clearly labelled
Smaller domestic consumer unit with each circuit clearly labelled

Testing schedule and remedials

The testing regime is two-tier. Monthly function tests are quick — flip the test key, watch the LED illuminate on battery, restore. The duty owner does these themselves and logs them in the logbook on site. The annual test is the substantive one. Each fitting runs on battery for its full duration rating (3 hours for HMO and residential applications), and any fitting that fails to make it the distance gets flagged for battery or fitting replacement. We document the results in the logbook and issue a fresh BS 5266 certificate against the new test date.

Why Rainham property owners book CJA Electrical

Three reasons most often. Emergency lighting work is done by a City & Guilds 2391 qualified inspector with ten years of working on Medway property — comfortable with HMO common-parts work, fire alarm circuit interfaces, and the kind of remediation jobs where an FRA has flagged something specific. Same-week appointments are typical for Rainham. Test certificates and logbook updates supplied at the end of each visit. Remedial fittings quoted alongside any failed-test findings so the duty owner has a single document to act on.

How the work runs

What a typical emergency lighting job in Rainham looks like: 1. Site visit — walk the building, identify escape routes, confirm fitting count and locations against the FRA or licence brief 2. Specification quoted — fitting type, duration rating, exit sign positions, test schedule 3. Installation in a single visit for most Rainham properties, two visits for larger blocks 4. Each fitting wired to a permanent live (regularly-used lighting circuit) and commissioned 5. Test on completion — non-maintained operation verified, duration test scheduled for the next maintenance visit 6. BS 5266 certificate issued plus a logbook stays at the property From first call to certificate is usually under a fortnight.

What affects the price

Pricing depends on the fitting count, the grade, and the access arrangements. For annual testing on existing systems, the price is per visit and per fitting — bigger systems with more fittings take longer and cost proportionally more. For remediation, the cost is the replacement fitting plus install labour. No published rate card because the variables matter. Same-day quote on receipt of the property and scope.

FAQs

How often does emergency lighting need testing?

Monthly function test (the duty owner does this) and an annual full-discharge test by a competent person. The annual test runs each fitting on battery for the full 3-hour duration to confirm it lasts the distance. CJA Electrical can do the annual test on systems we’ve installed and on systems installed by others — same workflow, same documentation.

Can you replace failed emergency lighting fittings in Rainham?

Yes. Failed fittings are usually a battery problem (typical 4-5 year life on older fluorescent units, 8-10 years on modern LED with sealed cells) or end-of-life on the fitting itself. We swap failed fittings on a like-for-like basis where the existing layout is sound, or rework the whole spec where a fire risk assessment has flagged gaps in coverage.

What documentation do you supply on completion?

BS 5266 certificate documenting the installation and the test results, plus a logbook for ongoing test records that stays at the property. The certificate is the document Medway Council fire risk assessors and insurers expect to see on inspection. Annual test visits update the logbook and issue a fresh dated certificate.

How long should emergency lights stay on after a power cut?

Depends on the duration rating and the application. 1-hour fittings are the minimum for premises with quick evacuation. 3-hour fittings are required for sleeping accommodation — HMOs, blocks of flats, hotels — because evacuation may be slower. We default to 3-hour LED for residential common-parts work in Rainham because the cost difference is minimal and the compliance posture is stronger.

Can you fit emergency lighting alongside a new fire alarm system?

Yes. The two systems are separate but related — fire alarm circuits and emergency lighting circuits typically share supply origins, so coordination matters. We do the emergency lighting side and can interface with whatever fire alarm contractor is doing the BS 5839-1 work. For HMOs in Rainham we often install the emergency lighting as part of the same licence-renewal scope as smoke alarm work — see the smoke alarm installation page for that side.

Related services in Rainham

Emergency Lighting in nearby towns

Frequently asked questions

How often does emergency lighting need testing?

Monthly function test (the duty owner does this) and an annual full-discharge test by a competent person. The annual test runs each fitting on battery for the full 3-hour duration to confirm it lasts the distance. CJA Electrical can do the annual test on systems we've installed and on systems installed by others — same workflow, same documentation.

Can you replace failed emergency lighting fittings in Rainham?

Yes. Failed fittings are usually a battery problem (typical 4-5 year life on older fluorescent units, 8-10 years on modern LED with sealed cells) or end-of-life on the fitting itself. We swap failed fittings on a like-for-like basis where the existing layout is sound, or rework the whole spec where a fire risk assessment has flagged gaps in coverage.

What documentation do you supply on completion?

BS 5266 certificate documenting the installation and the test results, plus a logbook for ongoing test records that stays at the property. The certificate is the document Medway Council fire risk assessors and insurers expect to see on inspection. Annual test visits update the logbook and issue a fresh dated certificate.

How long should emergency lights stay on after a power cut?

Depends on the duration rating and the application. 1-hour fittings are the minimum for premises with quick evacuation. 3-hour fittings are required for sleeping accommodation — HMOs, blocks of flats, hotels — because evacuation may be slower. We default to 3-hour LED for residential common-parts work in Rainham because the cost difference is minimal and the compliance posture is stronger.

Can you fit emergency lighting alongside a new fire alarm system?

Yes. The two systems are separate but related — fire alarm circuits and emergency lighting circuits typically share supply origins, so coordination matters. We do the emergency lighting side and can interface with whatever fire alarm contractor is doing the BS 5839-1 work. For HMOs in Rainham we often install the emergency lighting as part of the same licence-renewal scope as smoke alarm work — see the [smoke alarm installation page](/smoke-alarm-installation/) for that side.

Get a quote

Send a quick message and you'll get a same-day reply during working hours. Skip straight to phone or WhatsApp if you prefer.

EICR detail (helps with the quote)

Or skip the form: Call 07598 216512 WhatsApp info@cjaelectrical.co.uk