Fully labelled domestic consumer unit after EICR testing

Electrical Installation Condition Reports for Kings Hill property owners. The EICR is the formal piece of paper documenting that the fixed wiring in a house, flat, or commercial unit meets BS 7671 — the UK Wiring Regulations. Kings Hill is largely modern build (1990s onwards) — newer estates of detached and semi-detached housing alongside modern apartment blocks. EICR work here typically focuses on consumer unit RCD and SPD upgrades and the small remedials that come up at the 10-year point on a mid-life installation. The job runs out of Rochester and most Kings Hill appointments are available within the same week, with the report supplied as a PDF inside 48 hours of testing.

What EICR actually is

“EICR” is short for Electrical Installation Condition Report — the formal documentation of a fixed-wiring inspection at a specific point in time. It tells you the condition of the installation today, lists anything that doesn’t meet current regulations, and gives the property owner a punchlist of what needs putting right. The report is what’s accepted as evidence of compliance — by Tonbridge and Malling Borough Council for landlords subject to the 2020 PRS regulations, by surveyors during a sale, by insurers at renewal, and by managing agents at change of tenancy. Reports formatted to the BS 7671 standard layout are recognised universally across the industry.

When you need EICR in Kings Hill

Different reasons for different property types. Rented property in Kings Hill runs on the 2020 PRS regulations — five years between inspections, plus a fresh report at the start of each new tenancy. The certificate is supplied to tenants and to the local authority on request. Owner-occupied property doesn’t have a statutory cycle. IET guidance is 10 years for domestic, but plenty of homeowners inspect more frequently — usually around major life events like buying, selling, or renovating. Insurance renewals also trigger it, especially on older properties or where there’s been a previous claim.

Multi-occupancy meter cupboard with separate consumer units and smart meters
Multi-occupancy meter cupboard with separate consumer units and smart meters

Standards and what compliance looks like

The technical standard for an EICR is BS 7671:2018+A2:2022 — the 18th Edition of the IET Wiring Regulations with Amendment 2. Any EICR signed off after January 2023 should reference that version. Older reports against earlier amendments are still valid for the cycle they were issued in but should be re-tested to current standards on the next inspection. The format of the report itself follows BS 7671 Appendix 6 — schedule of inspections, schedule of test results, list of observations with codes. Reports formatted to that standard are accepted by every Tonbridge and Malling local authority, every insurer, and every estate agent we’ve worked with.

Fittings and where they go

Inspection scope is “what’s accessible without destruction” — we don’t lift floorboards or break into walls. The consumer unit comes off, every socket and switch plate is checked visually, every light fitting that’s reachable is inspected, and we go into lofts, cellars, outbuildings, and meter cupboards where they exist. For the hidden parts of the installation — buried cables, junctions inside walls — the live testing catches structural faults via insulation resistance (low values mean cable damage or moisture ingress) and earth fault loop impedance (high values mean a poor earth path). The combination of visual and test results is what builds the picture of installation condition.

Multifunction tester measuring end-to-end resistance on a ring final circuit
Multifunction tester measuring end-to-end resistance on a ring final circuit

Testing schedule and remedials

All testing uses calibrated multifunction test equipment — insulation resistance, earth fault loop impedance, RCD operation, and continuity all measured against the BS 7671 pass criteria for each test. Calibration certificates are available on request; the equipment is calibrated annually to UKAS standards. On site, the work runs circuit by circuit. Each is isolated, dead-tested, restored, and live-tested before moving on. The customer is kept informed of what’s being tested and any brief power-downs are flagged in advance. Our standard practice is to leave the consumer unit and accessories exactly as we found them once testing is complete.

Why Kings Hill property owners book CJA Electrical

Three things matter on EICR work and they all sit on the inspector: technical accuracy (the right observations coded correctly), report quality (clearly written, properly formatted to BS 7671 Appendix 6), and turnaround (the report in your hands inside 48 hours, not a week later). All three are why Tonbridge and Malling clients keep coming back. On the practical side: same-day quote, scheduled inspection inside the working week, PDF report direct to your inbox or your agent’s, and remedial work quoted line-by-line against the report so you can decide what to action.

How the work runs

Step one — quick chat about the property: how many bedrooms, rough age of the consumer unit, any known issues, any access constraints (tenanted property, occupied during works, working hours preferences). Most quotes are confirmed on that initial call as a fixed price, with larger or unusual properties going to a brief site visit before the quote firms up. Step two — testing visit. Half a day to a full day on site for most domestic property; longer for larger or multi-installation premises. Brief power-downs during dead testing flagged in advance. Step three — the report. PDF inside 48 hours, formatted to BS 7671 Appendix 6, with the schedule of test results, schedule of inspections, and observations all in the standard format insurers and agents expect to see.

What affects the price

Pricing is transparent: a fixed price for the inspection and report, separate quoting for remedials. The fixed price is set on a brief scoping call about the property — rough age, number of consumer units, circuit count if known, occupancy. Most Kings Hill domestic EICRs are quoted on that call alone. Larger properties — anything with multiple consumer units, significant outbuildings, three-phase commercial supply — get a capped quote after a quick site visit. The cap means you have certainty on the maximum cost going in, even if the on-site time runs slightly longer than expected.

FAQs

Can you do remedial work on the same visit?

Sometimes — minor remedials (replacing a damaged socket face, tightening a loose connection, fitting a missing blanking plate) can be done on the inspection visit if time and parts allow. Larger remedial work (consumer unit replacement, recircuiting, additional RCD protection) is quoted separately and scheduled as a follow-up.

Will the inspection damage anything?

No. The tests are non-destructive. Insulation resistance and earth fault loop are low-current measurements that don’t stress the installation. Most of the on-site work is visual inspection plus brief electrical testing on each circuit. The only disruption is the short power-downs during dead testing.

How quickly can I get a report after the inspection?

PDF inside 48 hours of testing completing. We can usually turn it around faster (same evening, next morning) if there’s a deadline — landlord renewal, sale exchange, insurance renewal — and we just need to know the deadline up front.

What if I disagree with an observation on the report?

Talk to us. Each observation has reasoning behind the coding — usually clear regulatory references — and we’ll walk through any specific item if you want to understand the call. Genuine reconsideration on borderline calls is fine; we don’t dig in for the sake of it.

Does an EICR cover gas, water, or appliances?

No. The EICR is a fixed-wiring inspection only — the consumer unit and circuits, plus accessories like sockets and switches. Gas certification is a Gas Safe registered engineer’s job; water leak detection is a plumber’s; appliance testing (PAT testing) is a separate service. We can refer to trusted local trades for any of those.

Related services in Kings Hill

EICR in nearby towns

Frequently asked questions

Can you do remedial work on the same visit?

Sometimes — minor remedials (replacing a damaged socket face, tightening a loose connection, fitting a missing blanking plate) can be done on the inspection visit if time and parts allow. Larger remedial work (consumer unit replacement, recircuiting, additional RCD protection) is quoted separately and scheduled as a follow-up.

Will the inspection damage anything?

No. The tests are non-destructive. Insulation resistance and earth fault loop are low-current measurements that don't stress the installation. Most of the on-site work is visual inspection plus brief electrical testing on each circuit. The only disruption is the short power-downs during dead testing.

How quickly can I get a report after the inspection?

PDF inside 48 hours of testing completing. We can usually turn it around faster (same evening, next morning) if there's a deadline — landlord renewal, sale exchange, insurance renewal — and we just need to know the deadline up front.

What if I disagree with an observation on the report?

Talk to us. Each observation has reasoning behind the coding — usually clear regulatory references — and we'll walk through any specific item if you want to understand the call. Genuine reconsideration on borderline calls is fine; we don't dig in for the sake of it.

Does an EICR cover gas, water, or appliances?

No. The EICR is a fixed-wiring inspection only — the consumer unit and circuits, plus accessories like sockets and switches. Gas certification is a Gas Safe registered engineer's job; water leak detection is a plumber's; appliance testing (PAT testing) is a separate service. We can refer to trusted local trades for any of those.

Get a quote

Send a quick message and you'll get a same-day reply during working hours. Skip straight to phone or WhatsApp if you prefer.

EICR detail (helps with the quote)