Office trunking and twin sockets in a commercial fit-out tested by CJA Electrical

CJA Electrical does commercial EICR and fixed wire testing across Snodland and the wider Tonbridge and Malling area. The legal framework for commercial premises is the Electricity at Work Regulations 1989 — and the EICR (also called fixed wire testing or periodic inspection) is the standard documentary evidence that the duty-holder is meeting that obligation. Whether you’re an office tenant, a retail unit operator, or a building owner with multi-tenanted commercial property, the inspection runs out of our Rochester base.

What Commercial EICR actually is

A commercial EICR is a periodic inspection and test of the fixed wiring in a commercial premises — the distribution board, sub-circuits, sockets, lighting, and fixed equipment connections. It’s the same fundamental process as a domestic EICR, but typically covers larger installations, three-phase supplies, and the kind of building services (emergency lighting interface, fire alarm interface, plant equipment) that don’t appear in residential. The output is a written report against BS 7671 with observation codes (C1, C2, C3, FI) on anything that doesn’t meet the regulations, plus a schedule of test results documenting what was actually measured. The duty-holder uses the report to plan remedial work and demonstrate compliance.

When you need Commercial EICR in Snodland

The standard inspection cycle for commercial premises follows IET Guidance Note 3. For most Snodland offices, retail units, and small workshops that’s five years. Industrial premises, educational buildings, and laboratories typically run on a three-year cycle. Higher-risk environments — cinemas, theatres, swimming pools, petrol stations, places of public assembly — sit on annual inspection. Beyond the periodic cycle, an EICR is commissioned at change of occupancy (new tenant taking over a unit), after major refurbishment, after a known fault or insurance claim, and on insurance request at policy renewal. We’ve also done a few in Snodland where a sale is in progress and the buyer’s surveyor has flagged the electrics for further investigation.

Inside a fully wired domestic consumer unit
Inside a fully wired domestic consumer unit

Standards and what compliance looks like

The two pieces of regulation that sit behind a commercial EICR are BS 7671:2018+A2:2022 (the IET Wiring Regulations — the technical standard the inspection works to) and the Electricity at Work Regulations 1989 (the legal duty on the employer or building owner to keep the installation safe and maintained). The EICR document itself follows the format set out in BS 7671 Appendix 6 — schedule of inspections, schedule of test results, list of observations with codes. Reports formatted to that standard are accepted by every insurer, every Tonbridge and Malling local authority, and every commercial landlord we’ve worked with.

Testing schedule and remedials

The testing itself splits into dead testing (with the circuit isolated) and live testing (with the supply restored). Dead tests cover continuity of protective conductors, insulation resistance between live and earth, polarity, and ring final continuity on sockets. Live tests cover earth fault loop impedance and RCD operation. Each circuit gets recorded individually on the schedule of test results that accompanies the certificate. On a typical Snodland commercial installation, the testing takes anywhere from half a day for a small office to two or three days for a multi-board industrial unit. We schedule the work around your trading hours — most offices and workshops can be done outside business hours, and retail units are usually best done early morning before opening.

RCD and loop impedance testing in progress on a domestic circuit
RCD and loop impedance testing in progress on a domestic circuit

Why Snodland property owners book CJA Electrical

We work with commercial clients across Snodland the same way we work with domestic clients: same-day quotes, clear communication on what the inspection involves, transparent pricing, and a written report inside 48 hours. The difference on commercial is just the scheduling — most jobs run outside trading hours or in phased blocks during quieter periods. Reports are formatted to the standard BS 7671 template that insurers, managing agents, and HSE inspectors expect. Remedial work — if the report is unsatisfactory — is quoted separately so the duty-holder can plan the budget and prioritise C1 and C2 observations first.

How the work runs

The process from first call to delivered certificate is straightforward. Initial chat (phone or email) to confirm the premises type, circuit count, board count, and access constraints. A quote — fixed price where possible, otherwise capped — covering the testing itself. A scheduled testing visit, typically out-of-hours for retail and during business hours for office. Report supplied as a PDF within 48 hours of testing completing, formatted to BS 7671 with all observations coded. If anything is unsatisfactory, remedial work gets quoted separately so you can decide which observations to clear first. Once the remedials are done, the affected circuits are re-tested and a fresh certificate issued reflecting the post-remedial state of the installation.

What affects the price

Commercial EICR pricing is driven by the size of the installation — number of circuits, number of distribution boards, total accessory count — and the access conditions. Most Snodland office EICRs come in as a fixed price after a five-minute scoping call. Industrial premises and multi-board commercial often need a brief site visit before the quote firms up. What’s included in the quote: the inspection, the testing, the written report formatted to BS 7671. What’s quoted separately: any remedial work needed to clear C1 or C2 observations after the report. We don’t bundle remedials into the inspection price — keeping them separate means the duty-holder can shop the remedial quote against other contractors if they want to.

FAQs

What documentation do I get at the end?

The Electrical Installation Condition Report itself (front page with verdict, schedule of inspections, schedule of test results, list of observations) as a single PDF. We can split it into board-specific certificates if you need separate documents for individual tenants in a multi-tenanted building. The PDF is what your insurer, Tonbridge and Malling Borough Council, and any future buyer’s surveyor will expect to see.

How often does a commercial EICR need doing?

IET Guidance Note 3 is the reference. Five years is standard for offices, retail, and most small commercial in Snodland. Three years for industrial, educational, and most workshop premises. One year for higher-risk environments — cinemas, swimming pools, places of public assembly. The duty-holder can shorten these intervals based on risk assessment, and most insurers require evidence the building is on cycle.

What law requires a commercial EICR?

The Electricity at Work Regulations 1989. Regulation 4(2) makes the duty-holder responsible for keeping the installation safe and maintained, and Regulation 16 makes the employer responsible for ensuring competent persons do the testing. The EICR is the standard documentary evidence of compliance with both. Insurers commonly require it as a condition of policy.

Can testing be done out of hours so we don’t shut the business?

Yes. Out-of-hours testing is the default for retail units, restaurants, and most Snodland commercial premises. We can also phase the testing across multiple visits if the building can’t sustain a single block. Tell us when you’re closed (or quietest) and we’ll plan the work to fit.

What’s a sampling EICR and is it appropriate for our building?

Sampling is when the duty-holder specifies a percentage (often 10–20%) of circuits and accessories to be tested rather than 100%. The remaining circuits are visually inspected only. The sample is documented on the report and the duty-holder accepts responsibility for the un-tested portion. Appropriate for large, low-risk premises on tight inspection cycles. For most Snodland commercial, full testing is the right call.

Related services in Snodland

Commercial EICR in nearby towns

Frequently asked questions

What documentation do I get at the end?

The Electrical Installation Condition Report itself (front page with verdict, schedule of inspections, schedule of test results, list of observations) as a single PDF. We can split it into board-specific certificates if you need separate documents for individual tenants in a multi-tenanted building. The PDF is what your insurer, Tonbridge and Malling Borough Council, and any future buyer's surveyor will expect to see.

How often does a commercial EICR need doing?

IET Guidance Note 3 is the reference. Five years is standard for offices, retail, and most small commercial in Snodland. Three years for industrial, educational, and most workshop premises. One year for higher-risk environments — cinemas, swimming pools, places of public assembly. The duty-holder can shorten these intervals based on risk assessment, and most insurers require evidence the building is on cycle.

What law requires a commercial EICR?

The Electricity at Work Regulations 1989. Regulation 4(2) makes the duty-holder responsible for keeping the installation safe and maintained, and Regulation 16 makes the employer responsible for ensuring competent persons do the testing. The EICR is the standard documentary evidence of compliance with both. Insurers commonly require it as a condition of policy.

Can testing be done out of hours so we don't shut the business?

Yes. Out-of-hours testing is the default for retail units, restaurants, and most Snodland commercial premises. We can also phase the testing across multiple visits if the building can't sustain a single block. Tell us when you're closed (or quietest) and we'll plan the work to fit.

What's a sampling EICR and is it appropriate for our building?

Sampling is when the duty-holder specifies a percentage (often 10–20%) of circuits and accessories to be tested rather than 100%. The remaining circuits are visually inspected only. The sample is documented on the report and the duty-holder accepts responsibility for the un-tested portion. Appropriate for large, low-risk premises on tight inspection cycles. For most Snodland commercial, full testing is the right call.

Get a quote

Send a quick message and you'll get a same-day reply during working hours. Skip straight to phone or WhatsApp if you prefer.

EICR detail (helps with the quote)

Or skip the form: Call 07598 216512 WhatsApp info@cjaelectrical.co.uk